Performed equipment evaluation and documentation for HVAC system replacement estimate. Inspected and photographed existing outdoor Rheem 4-ton air conditioner (Model RAMB-048JAZ, manufactured 12/2003) using R22 refrigerant, and indoor air handler unit located in attic with associated flexible ductwork and distribution system. Scheduled appointment to accommodate customer availability after work hours at 4pm to provide comprehensive replacement options and discuss equipment upgrade recommendations.
Performed equipment evaluation and documentation for HVAC system replacement estimate. Inspected and photographed existing outdoor Rheem 4-ton air conditioner (Model RAMB-048JAZ, manufactured 12/2003) using R22 refrigerant, and indoor air handler unit located in attic with associated flexible ductwork and distribution system. Scheduled appointment to accommodate customer availability after work hours at 4pm to provide comprehensive replacement options and discuss equipment upgrade recommendations.
Keagan M.
Keagan M. Checked in
Performed equipment evaluation and documentation for HVAC system replacement estimate. Inspected and photographed existing outdoor Rheem 4-ton air conditioner (Model RAMB-048JAZ, manufactured 12/2003) using R22 refrigerant, and indoor air handler unit located in attic with associated flexible ductwork and distribution system. Scheduled appointment to accommodate customer availability after work hours at 4pm to provide comprehensive replacement options and discuss equipment upgrade recommendations.
Geismar, LA 70734
Completed spring maintenance on two HVAC systems in residence. Performed system diagnostics using refrigeration manifold gauges to verify proper refrigerant pressures and temperatures on both units, inspected all mechanical components and utility connections in crawlspace area, and documented equipment conditions through photographic records to ensure both systems are operating within manufacturer specifications for the cooling season.
Completed spring maintenance on two HVAC systems in residence. Performed system diagnostics using refrigeration manifold gauges to verify proper refrigerant pressures and temperatures on both units, inspected all mechanical components and utility connections in crawlspace area, and documented equipment conditions through photographic records to ensure both systems are operating within manufacturer specifications for the cooling season.
Joshua B.
Joshua B. Checked in
Completed spring maintenance on two HVAC systems in residence. Performed system diagnostics using refrigeration manifold gauges to verify proper refrigerant pressures and temperatures on both units, inspected all mechanical components and utility connections in crawlspace area, and documented equipment conditions through photographic records to ensure both systems are operating within manufacturer specifications for the cooling season.
Geismar, LA 70734
Replaced two 25 MFD capacitors for the condenser fan motors on the right front unit. Obtained the required capacitors and returned to complete the installation, restoring proper operation to the system.
Replaced two 25 MFD capacitors for the condenser fan motors on the right front unit. Obtained the required capacitors and returned to complete the installation, restoring proper operation to the system.
Joshua B.
Joshua B. Checked in
Replaced two 25 MFD capacitors for the condenser fan motors on the right front unit. Obtained the required capacitors and returned to complete the installation, restoring proper operation to the system.
Geismar, LA 70734
Completed spring maintenance on four commercial HVAC systems. Performed comprehensive system inspections including electrical component testing, capacitor readings, and operational checks on all units. Measured voltage and amperage on multiple systems using clamp meter to verify proper electrical performance. Reviewed system documentation and technical manuals on-site to ensure proper specifications. Customer-supplied filters were installed on all four units as part of routine maintenance protocol. Previously identified need for two 25 mfd capacitors; returned to site to replace failed capacitors and restore full system functionality. All four systems tested and confirmed operational following maintenance and repairs. Coordinated arrival time with customer as requested and documented work with photographs of electrical compartments and diagnostic readings.
Completed spring maintenance on four commercial HVAC systems. Performed comprehensive system inspections including electrical component testing, capacitor readings, and operational checks on all units. Measured voltage and amperage on multiple systems using clamp meter to verify proper electrical performance. Reviewed system documentation and technical manuals on-site to ensure proper specifications. Customer-supplied filters were installed on all four units as part of routine maintenance protocol. Previously identified need for two 25 mfd capacitors; returned to site to replace failed capacitors and restore full system functionality. All four systems tested and confirmed operational following maintenance and repairs. Coordinated arrival time with customer as requested and documented work with photographs of electrical compartments and diagnostic readings.
Joshua B.
Joshua B. Checked in
Completed spring maintenance on four commercial HVAC systems. Performed comprehensive system inspections including electrical component testing, capacitor readings, and operational checks on all units. Measured voltage and amperage on multiple systems using clamp meter to verify proper electrical performance. Reviewed system documentation and technical manuals on-site to ensure proper specifications. Customer-supplied filters were installed on all four units as part of routine maintenance protocol. Previously identified need for two 25 mfd capacitors; returned to site to replace failed capacitors and restore full system functionality. All four systems tested and confirmed operational following maintenance and repairs. Coordinated arrival time with customer as requested and documented work with photographs of electrical compartments and diagnostic readings.
Geismar, LA 70734
Completed installation of Amana 5-ton air handler with 20 kw heat kit in attic space, including connection to existing ductwork system and electrical service. Unit is covered under 10-year parts and 1-year labor warranty.
Completed installation of Amana 5-ton air handler with 20 kw heat kit in attic space, including connection to existing ductwork system and electrical service. Unit is covered under 10-year parts and 1-year labor warranty.
Taylor B.
Taylor B. Checked in
Completed installation of Amana 5-ton air handler with 20 kw heat kit in attic space, including connection to existing ductwork system and electrical service. Unit is covered under 10-year parts and 1-year labor warranty.
Geismar, LA 70734
Completed spring maintenance on one HVAC unit located in attic space. Performed standard preventive maintenance inspection of system components, ductwork, and surrounding mechanical equipment. Follow-up visit scheduled to add R32 refrigerant to system after 2:30 PM to complete service requirements.
Completed spring maintenance on one HVAC unit located in attic space. Performed standard preventive maintenance inspection of system components, ductwork, and surrounding mechanical equipment. Follow-up visit scheduled to add R32 refrigerant to system after 2:30 PM to complete service requirements.
Joshua B.
Joshua B. Checked in
Completed spring maintenance on one HVAC unit located in attic space. Performed standard preventive maintenance inspection of system components, ductwork, and surrounding mechanical equipment. Follow-up visit scheduled to add R32 refrigerant to system after 2:30 PM to complete service requirements.
Geismar, LA 70734
Assessed non-functional wall-mounted HVAC unit serving training room area. Documented existing Harv Air outdoor condensing unit with weathered exterior cabinet showing significant dirt accumulation and discoloration. Reviewed unit specifications including 208/230 VAC outdoor air motor and compressor electrical parameters. Provided replacement quote for failed equipment.
Assessed non-functional wall-mounted HVAC unit serving training room area. Documented existing Harv Air outdoor condensing unit with weathered exterior cabinet showing significant dirt accumulation and discoloration. Reviewed unit specifications including 208/230 VAC outdoor air motor and compressor electrical parameters. Provided replacement quote for failed equipment.
Keagan M.
Keagan M. Checked in
Assessed non-functional wall-mounted HVAC unit serving training room area. Documented existing Harv Air outdoor condensing unit with weathered exterior cabinet showing significant dirt accumulation and discoloration. Reviewed unit specifications including 208/230 VAC outdoor air motor and compressor electrical parameters. Provided replacement quote for failed equipment.