Services — Geismar, LA

Expert Geismar, LA

AC Repair specialists serving Geismar, LA.

Get an Estimate

Recent Jobs and Reviews in Geismar, LA

Rated 5.0 out of 5 stars based on 1 customer reviews

Customers say: The overall sentiment across these reviews is overwhelmingly positive, reflecting strong customer satisfaction and trust in the company's services. Customers consistently express appreciation for the professionalism, thoroughness, and knowledge demonstrated by the service team. A dominant theme is the technicians' ability to communicate clearly, with reviewers frequently highlighting how well procedures and recommendations were explained in understandable terms. The company earns praise for its reliability, with mentions of long-term customer relationships and consistent quality service. Responsiveness and friendliness emerge as recurring positive attributes, from initial office contact through service completion. Customers value the attention to detail, timely service, and proactive problem-solving that prevents future issues. The reviews convey a sense of trust and comfort, with clients expressing confidence in the recommendations provided and the integrity of the work performed. The tone is enthusiastic and appreciative, with customers emphasizing their willingness to recommend the company to others. Overall, the sentiment reflects a highly regarded business that delivers excellent customer experiences through knowledgeable staff, transparent communication, and quality workmanship.

Our Local Reviews by City

Job Locations and Reviews

Review
Did their work fast, and were very friendly. Taylor and AJ were great! Thank y’all!
Jared - Geismar, LA 70734
Replaced defective thermal expansion valve (TXV) and liquid line filter drier under warranty on HVAC system. Retrieved replacement parts from Carrier supply house and performed complete component installation. Verified proper system operation using Fluke 325 clamp meter to confirm electrical readings of 9.70 amps and Fieldpiece SMAN manifold gauge set to monitor refrigerant pressures and temperatures throughout the process. System tested and operating within manufacturer specifications upon completion.
Replaced defective thermal expansion valve (TXV) and liquid line filter drier under warranty on HVAC system. Retrieved replacement parts from Carrier supply house and performed complete component installation. Verified proper system operation using Fluke 325 clamp meter to confirm electrical readings of 9.70 amps and Fieldpiece SMAN manifold gauge set to monitor refrigerant pressures and temperatures throughout the process. System tested and operating within manufacturer specifications upon completion.
Taylor B.
Taylor B. Checked in
Replaced defective thermal expansion valve (TXV) and liquid line filter drier under warranty on HVAC system. Retrieved replacement parts from Carrier supply house and performed complete component installation. Verified proper system operation using Fluke 325 clamp meter to confirm electrical readings of 9.70 amps and Fieldpiece SMAN manifold gauge set to monitor refrigerant pressures and temperatures throughout the process. System tested and operating within manufacturer specifications upon completion.
Geismar, LA 70734
Performed diagnostic evaluation of HVAC system refrigerant levels and electrical components. Utilized Fluke 325 True RMS clamp meter to verify electrical current draw, measuring 9.70 amps at the condensing unit. Connected Fieldpiece SMAN refrigerant manifold gauge to system, recording operating pressures and monitoring refrigerant charge. System analysis indicated low refrigerant levels requiring additional charge to restore proper operating parameters and optimize cooling performance.
Performed diagnostic evaluation of HVAC system refrigerant levels and electrical components. Utilized Fluke 325 True RMS clamp meter to verify electrical current draw, measuring 9.70 amps at the condensing unit. Connected Fieldpiece SMAN refrigerant manifold gauge to system, recording operating pressures and monitoring refrigerant charge. System analysis indicated low refrigerant levels requiring additional charge to restore proper operating parameters and optimize cooling performance.
Joshua B.
Joshua B. Checked in
Performed diagnostic evaluation of HVAC system refrigerant levels and electrical components. Utilized Fluke 325 True RMS clamp meter to verify electrical current draw, measuring 9.70 amps at the condensing unit. Connected Fieldpiece SMAN refrigerant manifold gauge to system, recording operating pressures and monitoring refrigerant charge. System analysis indicated low refrigerant levels requiring additional charge to restore proper operating parameters and optimize cooling performance.
Geismar, LA 70734
Geismar, LA - Completed installation of 3-ton Amana air handler system as specified in purchase order. Unit installed and positioned on concrete pad with proper clearance from adjacent structure, ensuring adequate airflow for optimal heat exchange and system performance. Installation verified with photographic documentation showing completed work and proper equipment placement.
Taylor B.
Taylor B. Checked in
Completed installation of 3-ton Amana air handler system as specified in purchase order. Unit installed and positioned on concrete pad with proper clearance from adjacent structure, ensuring adequate airflow for optimal heat exchange and system performance. Installation verified with photographic documentation showing completed work and proper equipment placement.
Geismar, LA 70734
Completed comprehensive maintenance on two HVAC systems - one electric air handler with gas furnace and one outdoor condensing unit. Performed standard preventative maintenance procedures including inspection of all electrical connections, control boards, and capacitors. Verified proper operation of both systems. Customer enrolled in maintenance club program. All components found in good working condition with no repairs required at this time.
Completed comprehensive maintenance on two HVAC systems - one electric air handler with gas furnace and one outdoor condensing unit. Performed standard preventative maintenance procedures including inspection of all electrical connections, control boards, and capacitors. Verified proper operation of both systems. Customer enrolled in maintenance club program. All components found in good working condition with no repairs required at this time.
Taylor B.
Taylor B. Checked in
Completed comprehensive maintenance on two HVAC systems - one electric air handler with gas furnace and one outdoor condensing unit. Performed standard preventative maintenance procedures including inspection of all electrical connections, control boards, and capacitors. Verified proper operation of both systems. Customer enrolled in maintenance club program. All components found in good working condition with no repairs required at this time.
Geismar, LA 70734
Completed comprehensive spring maintenance on single-system HVAC unit with Rheem air handler located in attic space. Performed standard seasonal inspection including filter check, electrical connections verification, refrigerant line inspection, condensate drain evaluation, and visual assessment of all accessible components and ductwork, with photographic documentation of equipment condition and installation area.
Completed comprehensive spring maintenance on single-system HVAC unit with Rheem air handler located in attic space. Performed standard seasonal inspection including filter check, electrical connections verification, refrigerant line inspection, condensate drain evaluation, and visual assessment of all accessible components and ductwork, with photographic documentation of equipment condition and installation area.
Joshua B.
Joshua B. Checked in
Completed comprehensive spring maintenance on single-system HVAC unit with Rheem air handler located in attic space. Performed standard seasonal inspection including filter check, electrical connections verification, refrigerant line inspection, condensate drain evaluation, and visual assessment of all accessible components and ductwork, with photographic documentation of equipment condition and installation area.
Geismar, LA 70734
Performed equipment evaluation and documentation for HVAC system replacement estimate. Inspected and photographed existing outdoor Rheem 4-ton air conditioner (Model RAMB-048JAZ, manufactured 12/2003) using R22 refrigerant, and indoor air handler unit located in attic with associated flexible ductwork and distribution system. Scheduled appointment to accommodate customer availability after work hours at 4pm to provide comprehensive replacement options and discuss equipment upgrade recommendations.
Performed equipment evaluation and documentation for HVAC system replacement estimate. Inspected and photographed existing outdoor Rheem 4-ton air conditioner (Model RAMB-048JAZ, manufactured 12/2003) using R22 refrigerant, and indoor air handler unit located in attic with associated flexible ductwork and distribution system. Scheduled appointment to accommodate customer availability after work hours at 4pm to provide comprehensive replacement options and discuss equipment upgrade recommendations.
Keagan M.
Keagan M. Checked in
Performed equipment evaluation and documentation for HVAC system replacement estimate. Inspected and photographed existing outdoor Rheem 4-ton air conditioner (Model RAMB-048JAZ, manufactured 12/2003) using R22 refrigerant, and indoor air handler unit located in attic with associated flexible ductwork and distribution system. Scheduled appointment to accommodate customer availability after work hours at 4pm to provide comprehensive replacement options and discuss equipment upgrade recommendations.
Geismar, LA 70734
Completed spring maintenance on two HVAC systems in residence. Performed system diagnostics using refrigeration manifold gauges to verify proper refrigerant pressures and temperatures on both units, inspected all mechanical components and utility connections in crawlspace area, and documented equipment conditions through photographic records to ensure both systems are operating within manufacturer specifications for the cooling season.
Completed spring maintenance on two HVAC systems in residence. Performed system diagnostics using refrigeration manifold gauges to verify proper refrigerant pressures and temperatures on both units, inspected all mechanical components and utility connections in crawlspace area, and documented equipment conditions through photographic records to ensure both systems are operating within manufacturer specifications for the cooling season.
Joshua B.
Joshua B. Checked in
Completed spring maintenance on two HVAC systems in residence. Performed system diagnostics using refrigeration manifold gauges to verify proper refrigerant pressures and temperatures on both units, inspected all mechanical components and utility connections in crawlspace area, and documented equipment conditions through photographic records to ensure both systems are operating within manufacturer specifications for the cooling season.
Geismar, LA 70734
Replaced two 25 MFD capacitors for the condenser fan motors on the right front unit. Obtained the required capacitors and returned to complete the installation, restoring proper operation to the system.
Replaced two 25 MFD capacitors for the condenser fan motors on the right front unit. Obtained the required capacitors and returned to complete the installation, restoring proper operation to the system.
Joshua B.
Joshua B. Checked in
Replaced two 25 MFD capacitors for the condenser fan motors on the right front unit. Obtained the required capacitors and returned to complete the installation, restoring proper operation to the system.
Geismar, LA 70734
Completed spring maintenance on four commercial HVAC systems. Performed comprehensive system inspections including electrical component testing, capacitor readings, and operational checks on all units. Measured voltage and amperage on multiple systems using clamp meter to verify proper electrical performance. Reviewed system documentation and technical manuals on-site to ensure proper specifications. Customer-supplied filters were installed on all four units as part of routine maintenance protocol. Previously identified need for two 25 mfd capacitors; returned to site to replace failed capacitors and restore full system functionality. All four systems tested and confirmed operational following maintenance and repairs. Coordinated arrival time with customer as requested and documented work with photographs of electrical compartments and diagnostic readings.
Completed spring maintenance on four commercial HVAC systems. Performed comprehensive system inspections including electrical component testing, capacitor readings, and operational checks on all units. Measured voltage and amperage on multiple systems using clamp meter to verify proper electrical performance. Reviewed system documentation and technical manuals on-site to ensure proper specifications. Customer-supplied filters were installed on all four units as part of routine maintenance protocol. Previously identified need for two 25 mfd capacitors; returned to site to replace failed capacitors and restore full system functionality. All four systems tested and confirmed operational following maintenance and repairs. Coordinated arrival time with customer as requested and documented work with photographs of electrical compartments and diagnostic readings.
Joshua B.
Joshua B. Checked in
Completed spring maintenance on four commercial HVAC systems. Performed comprehensive system inspections including electrical component testing, capacitor readings, and operational checks on all units. Measured voltage and amperage on multiple systems using clamp meter to verify proper electrical performance. Reviewed system documentation and technical manuals on-site to ensure proper specifications. Customer-supplied filters were installed on all four units as part of routine maintenance protocol. Previously identified need for two 25 mfd capacitors; returned to site to replace failed capacitors and restore full system functionality. All four systems tested and confirmed operational following maintenance and repairs. Coordinated arrival time with customer as requested and documented work with photographs of electrical compartments and diagnostic readings.
Geismar, LA 70734
Completed installation of Amana 5-ton air handler with 20 kw heat kit in attic space, including connection to existing ductwork system and electrical service. Unit is covered under 10-year parts and 1-year labor warranty.
Completed installation of Amana 5-ton air handler with 20 kw heat kit in attic space, including connection to existing ductwork system and electrical service. Unit is covered under 10-year parts and 1-year labor warranty.
Taylor B.
Taylor B. Checked in
Completed installation of Amana 5-ton air handler with 20 kw heat kit in attic space, including connection to existing ductwork system and electrical service. Unit is covered under 10-year parts and 1-year labor warranty.
Geismar, LA 70734
Completed spring maintenance on one HVAC unit located in attic space. Performed standard preventive maintenance inspection of system components, ductwork, and surrounding mechanical equipment. Follow-up visit scheduled to add R32 refrigerant to system after 2:30 PM to complete service requirements.
Completed spring maintenance on one HVAC unit located in attic space. Performed standard preventive maintenance inspection of system components, ductwork, and surrounding mechanical equipment. Follow-up visit scheduled to add R32 refrigerant to system after 2:30 PM to complete service requirements.
Joshua B.
Joshua B. Checked in
Completed spring maintenance on one HVAC unit located in attic space. Performed standard preventive maintenance inspection of system components, ductwork, and surrounding mechanical equipment. Follow-up visit scheduled to add R32 refrigerant to system after 2:30 PM to complete service requirements.
Geismar, LA 70734
Assessed non-functional wall-mounted HVAC unit serving training room area. Documented existing Harv Air outdoor condensing unit with weathered exterior cabinet showing significant dirt accumulation and discoloration. Reviewed unit specifications including 208/230 VAC outdoor air motor and compressor electrical parameters. Provided replacement quote for failed equipment.
Assessed non-functional wall-mounted HVAC unit serving training room area. Documented existing Harv Air outdoor condensing unit with weathered exterior cabinet showing significant dirt accumulation and discoloration. Reviewed unit specifications including 208/230 VAC outdoor air motor and compressor electrical parameters. Provided replacement quote for failed equipment.
Keagan M.
Keagan M. Checked in
Assessed non-functional wall-mounted HVAC unit serving training room area. Documented existing Harv Air outdoor condensing unit with weathered exterior cabinet showing significant dirt accumulation and discoloration. Reviewed unit specifications including 208/230 VAC outdoor air motor and compressor electrical parameters. Provided replacement quote for failed equipment.
Geismar, LA 70734

Ready to schedule?

Book this service today and secure your preferred time.

Book now

Frequently Asked Questions

Answer common concerns before visitors call