Customers say: The overall sentiment is overwhelmingly positive, marked by warmth, gratitude, and strong satisfaction. Reviewers consistently praise the technicians' professionalism, politeness, and friendly demeanor, often describing the service as exceptional or beyond expectations. A dominant theme is clear communication: customers appreciate that everything was explained in plain, understandable terms, that questions were answered patiently and thoroughly, and that recommendations were presented transparently without any sense of pressure to buy unnecessary services. Punctuality and reliable scheduling updates from the office are also recurring points of approval, as is the speed and efficiency with which problems were diagnosed and resolved. Many reviewers express relief and appreciation that long-standing or frustrating issues were finally fixed, noting improved comfort and system performance in their homes. Fair pricing, attention to detail, tidiness, and going the extra mile, such as providing additional options or temporary solutions, further reinforce the sense of trust and confidence. Overall, customers express pride, loyalty, and a strong willingness to recommend the company and use its services again.

Baton Rouge, LA at a glance

GeauxHVAC has completed 25 jobs in Baton Rouge, LA between October 2026 and November 2026.

The 14 customer reviews shown here average 5.0 out of 5.

The most recent job was on November 10, 2026.

GeauxHVAC has completed 203 jobs in Baton Rouge, LA in the last 12 months.

Job Locations and Reviews

Performed a fall heating tune-up on one system, including inspection of the air handler cabinet, blower assembly, and filter, where dust and debris buildup was noted on the blower wheel blades. Verified furnace operation by measuring electrical readings with a true RMS clamp meter at the blower motor and control wiring, and inspected the gas valve, burner section, and wiring harness, finding no visible signs of rust, frost, or component damage.
Performed a fall heating tune-up on one system, including inspection of the air handler cabinet, blower assembly, and filter, where dust and debris buildup was noted on the blower wheel blades. Verified furnace operation by measuring electrical readings with a true RMS clamp meter at the blower motor and control wiring, and inspected the gas valve, burner section, and wiring harness, finding no visible signs of rust, frost, or component damage.
Asters D.
Asters D. Checked in
Performed a fall heating tune-up on one system, including inspection of the air handler cabinet, blower assembly, and filter, where dust and debris buildup was noted on the blower wheel blades. Verified furnace operation by measuring electrical readings with a true RMS clamp meter at the blower motor and control wiring, and inspected the gas valve, burner section, and wiring harness, finding no visible signs of rust, frost, or component damage.
Baton Rouge, LA 70808
Performed a seasonal heating system tune-up, inspecting the furnace cabinet, internal wiring, and flue and gas components, and verifying electrical operation with a clamp meter (51.2 reading recorded on the monitored circuit). Inspected the 20x25x5 media air filter, which was heavily loaded with dust and debris, and noted it for replacement to restore proper airflow. No rust, frost, or visible damage was found inside the unit cabinet.
Performed a seasonal heating system tune-up, inspecting the furnace cabinet, internal wiring, and flue and gas components, and verifying electrical operation with a clamp meter (51.2 reading recorded on the monitored circuit). Inspected the 20x25x5 media air filter, which was heavily loaded with dust and debris, and noted it for replacement to restore proper airflow. No rust, frost, or visible damage was found inside the unit cabinet.
Asters D.
Asters D. Checked in
Performed a seasonal heating system tune-up, inspecting the furnace cabinet, internal wiring, and flue and gas components, and verifying electrical operation with a clamp meter (51.2 reading recorded on the monitored circuit). Inspected the 20x25x5 media air filter, which was heavily loaded with dust and debris, and noted it for replacement to restore proper airflow. No rust, frost, or visible damage was found inside the unit cabinet.
Baton Rouge, LA 70808
Performed a fall tune-up on the gas heating system, including inspection of the furnace cabinet, gas valve, wiring harness, and inducer motor assembly, and verified low-voltage control circuit operation with a clamp meter (6.2 reading). Inspected the evaporator coil and header and noted significant oxidation, rust, and debris buildup on the coil and drain pan area, recommending further evaluation and cleaning to maintain system efficiency and prevent component failure.
Performed a fall tune-up on the gas heating system, including inspection of the furnace cabinet, gas valve, wiring harness, and inducer motor assembly, and verified low-voltage control circuit operation with a clamp meter (6.2 reading). Inspected the evaporator coil and header and noted significant oxidation, rust, and debris buildup on the coil and drain pan area, recommending further evaluation and cleaning to maintain system efficiency and prevent component failure.
Asters D.
Asters D. Checked in
Performed a fall tune-up on the gas heating system, including inspection of the furnace cabinet, gas valve, wiring harness, and inducer motor assembly, and verified low-voltage control circuit operation with a clamp meter (6.2 reading). Inspected the evaporator coil and header and noted significant oxidation, rust, and debris buildup on the coil and drain pan area, recommending further evaluation and cleaning to maintain system efficiency and prevent component failure.
Baton Rouge, LA 70808
Performed a fall heating tune-up on one system, inspecting the electric heat strip assembly and confirming the resistance coils were intact, evenly spaced, and properly supported by ceramic insulators with only minor dust accumulation. Verified electrical operation by measuring amp draw at the outdoor unit's electrical compartment with a clamp meter (11.94 A), and checked the contactor and wiring connections for proper condition.
Performed a fall heating tune-up on one system, inspecting the electric heat strip assembly and confirming the resistance coils were intact, evenly spaced, and properly supported by ceramic insulators with only minor dust accumulation. Verified electrical operation by measuring amp draw at the outdoor unit's electrical compartment with a clamp meter (11.94 A), and checked the contactor and wiring connections for proper condition.
Asters D.
Asters D. Checked in
Performed a fall heating tune-up on one system, inspecting the electric heat strip assembly and confirming the resistance coils were intact, evenly spaced, and properly supported by ceramic insulators with only minor dust accumulation. Verified electrical operation by measuring amp draw at the outdoor unit's electrical compartment with a clamp meter (11.94 A), and checked the contactor and wiring connections for proper condition.
Baton Rouge, LA 70817
Performed a fall tune-up on one system, inspecting the evaporator coil and cabinet interior and noting dust buildup, mineral deposits, and surface corrosion on the casing and brackets, along with stained insulation on the refrigerant line. Verified electrical operation by measuring amperage draw (19.35 A) with a true RMS clamp meter and inspecting the low-voltage wiring connections and contactor for proper condition.
Performed a fall tune-up on one system, inspecting the evaporator coil and cabinet interior and noting dust buildup, mineral deposits, and surface corrosion on the casing and brackets, along with stained insulation on the refrigerant line. Verified electrical operation by measuring amperage draw (19.35 A) with a true RMS clamp meter and inspecting the low-voltage wiring connections and contactor for proper condition.
Asters D.
Asters D. Checked in
Performed a fall tune-up on one system, inspecting the evaporator coil and cabinet interior and noting dust buildup, mineral deposits, and surface corrosion on the casing and brackets, along with stained insulation on the refrigerant line. Verified electrical operation by measuring amperage draw (19.35 A) with a true RMS clamp meter and inspecting the low-voltage wiring connections and contactor for proper condition.
Baton Rouge, LA 70817
Performed an on-site assessment for a complete ductwork replacement, documenting the air handler dimensions (approx. 20.9" x 20.5"), a 12-run duct layout, and room-by-room branch sizing. Developed a room-by-room load and airflow (CFM) layout from the floor plan to support proper duct design and sizing for the replacement estimate.
Performed an on-site assessment for a complete ductwork replacement, documenting the air handler dimensions (approx. 20.9" x 20.5"), a 12-run duct layout, and room-by-room branch sizing. Developed a room-by-room load and airflow (CFM) layout from the floor plan to support proper duct design and sizing for the replacement estimate.
Keagan M.
Keagan M. Checked in
Performed an on-site assessment for a complete ductwork replacement, documenting the air handler dimensions (approx. 20.9" x 20.5"), a 12-run duct layout, and room-by-room branch sizing. Developed a room-by-room load and airflow (CFM) layout from the floor plan to support proper duct design and sizing for the replacement estimate.
Baton Rouge, LA 70808
Performed a fall heater tune-up on one system, inspecting the evaporator coil, which showed dust accumulation on the fins along with rust and corrosion on the coil frame and lower drain pan. Inspected the attic ductwork and found heavily soiled, deteriorated duct wrap and insulation with staining consistent with moisture exposure, as well as rusted metal brackets, which are possible contributors to the reported popping noise at startup and shutdown (likely duct expansion and contraction). Recommend further evaluation of the duct insulation and corroded components.
Performed a fall heater tune-up on one system, inspecting the evaporator coil, which showed dust accumulation on the fins along with rust and corrosion on the coil frame and lower drain pan. Inspected the attic ductwork and found heavily soiled, deteriorated duct wrap and insulation with staining consistent with moisture exposure, as well as rusted metal brackets, which are possible contributors to the reported popping noise at startup and shutdown (likely duct expansion and contraction). Recommend further evaluation of the duct insulation and corroded components.
Asters D.
Asters D. Checked in
Performed a fall heater tune-up on one system, inspecting the evaporator coil, which showed dust accumulation on the fins along with rust and corrosion on the coil frame and lower drain pan. Inspected the attic ductwork and found heavily soiled, deteriorated duct wrap and insulation with staining consistent with moisture exposure, as well as rusted metal brackets, which are possible contributors to the reported popping noise at startup and shutdown (likely duct expansion and contraction). Recommend further evaluation of the duct insulation and corroded components.
Baton Rouge, LA 70817
Performed seasonal tune-up on gas furnace, inspecting burner assembly and confirming stable blue flame pattern with proper ignition and flame sensing. Verified gas valve and pipe connections, and measured blower and inducer motor amperage with a clamp meter to confirm normal electrical operation. Inspected pressure switches, wiring, and cabinet interior, finding no signs of corrosion, frost, or damage, and the system is operating normally.
Performed seasonal tune-up on gas furnace, inspecting burner assembly and confirming stable blue flame pattern with proper ignition and flame sensing. Verified gas valve and pipe connections, and measured blower and inducer motor amperage with a clamp meter to confirm normal electrical operation. Inspected pressure switches, wiring, and cabinet interior, finding no signs of corrosion, frost, or damage, and the system is operating normally.
Joshua B.
Joshua B. Checked in
Performed seasonal tune-up on gas furnace, inspecting burner assembly and confirming stable blue flame pattern with proper ignition and flame sensing. Verified gas valve and pipe connections, and measured blower and inducer motor amperage with a clamp meter to confirm normal electrical operation. Inspected pressure switches, wiring, and cabinet interior, finding no signs of corrosion, frost, or damage, and the system is operating normally.
Baton Rouge, LA 70810
Responded to a complaint of one of two systems blowing air without adequate cooling. Inspected the outdoor electrical disconnect and found the cover removed, with accumulated dirt, debris, and nesting material around the conduit entry, along with aged wire insulation and splices secured with twist-on connectors. Documented the disconnect condition, which may be contributing to the system's reduced cooling performance, and further diagnostics of the 3-year-old unit's cooling components are recommended under warranty.
Responded to a complaint of one of two systems blowing air without adequate cooling. Inspected the outdoor electrical disconnect and found the cover removed, with accumulated dirt, debris, and nesting material around the conduit entry, along with aged wire insulation and splices secured with twist-on connectors. Documented the disconnect condition, which may be contributing to the system's reduced cooling performance, and further diagnostics of the 3-year-old unit's cooling components are recommended under warranty.
Joshua B.
Joshua B. Checked in
Responded to a complaint of one of two systems blowing air without adequate cooling. Inspected the outdoor electrical disconnect and found the cover removed, with accumulated dirt, debris, and nesting material around the conduit entry, along with aged wire insulation and splices secured with twist-on connectors. Documented the disconnect condition, which may be contributing to the system's reduced cooling performance, and further diagnostics of the 3-year-old unit's cooling components are recommended under warranty.
Baton Rouge, LA 70808
Performed fall tune-up on two gas furnace systems, inspecting internal components including the pressure switch, inducer motor, gas valve, flexible gas line, and low-voltage and line-voltage wiring. Verified electrical operation with a true RMS clamp meter, measuring amperage draw on the motor circuit at 12.69 A AC. Noted heavy dust, corrosion, and rust buildup on interior cabinet surfaces and components, and documented the unit's condition for ongoing maintenance.
Performed fall tune-up on two gas furnace systems, inspecting internal components including the pressure switch, inducer motor, gas valve, flexible gas line, and low-voltage and line-voltage wiring. Verified electrical operation with a true RMS clamp meter, measuring amperage draw on the motor circuit at 12.69 A AC. Noted heavy dust, corrosion, and rust buildup on interior cabinet surfaces and components, and documented the unit's condition for ongoing maintenance.
Asters D.
Asters D. Checked in
Performed fall tune-up on two gas furnace systems, inspecting internal components including the pressure switch, inducer motor, gas valve, flexible gas line, and low-voltage and line-voltage wiring. Verified electrical operation with a true RMS clamp meter, measuring amperage draw on the motor circuit at 12.69 A AC. Noted heavy dust, corrosion, and rust buildup on interior cabinet surfaces and components, and documented the unit's condition for ongoing maintenance.
Baton Rouge, LA 70818
Performed a fall tune-up on the gas furnace, inspecting the gas valve assembly, flexible gas line connections, and control wiring, and verifying operation with a Fieldpiece probe. Noted dust and debris buildup in the furnace cabinet, along with a torn, deteriorated insulated flex duct end in the attic with exposed fiberglass, which is recommended for repair or replacement to prevent air loss and efficiency issues.
Performed a fall tune-up on the gas furnace, inspecting the gas valve assembly, flexible gas line connections, and control wiring, and verifying operation with a Fieldpiece probe. Noted dust and debris buildup in the furnace cabinet, along with a torn, deteriorated insulated flex duct end in the attic with exposed fiberglass, which is recommended for repair or replacement to prevent air loss and efficiency issues.
Asters D.
Asters D. Checked in
Performed a fall tune-up on the gas furnace, inspecting the gas valve assembly, flexible gas line connections, and control wiring, and verifying operation with a Fieldpiece probe. Noted dust and debris buildup in the furnace cabinet, along with a torn, deteriorated insulated flex duct end in the attic with exposed fiberglass, which is recommended for repair or replacement to prevent air loss and efficiency issues.
Baton Rouge, LA 70816
Performed a fall tune-up on the gas furnace, inspecting the gas valve, flexible gas line connection, pressure switch, burner and heat exchanger area, and control wiring for wear, leaks, and damage. Used a clamp meter to verify electrical operation of the furnace components, with no frost, rust, or visible damage observed, and cleared accumulated dust and debris from the cabinet to support safe, efficient operation.
Performed a fall tune-up on the gas furnace, inspecting the gas valve, flexible gas line connection, pressure switch, burner and heat exchanger area, and control wiring for wear, leaks, and damage. Used a clamp meter to verify electrical operation of the furnace components, with no frost, rust, or visible damage observed, and cleared accumulated dust and debris from the cabinet to support safe, efficient operation.
Asters D.
Asters D. Checked in
Performed a fall tune-up on the gas furnace, inspecting the gas valve, flexible gas line connection, pressure switch, burner and heat exchanger area, and control wiring for wear, leaks, and damage. Used a clamp meter to verify electrical operation of the furnace components, with no frost, rust, or visible damage observed, and cleared accumulated dust and debris from the cabinet to support safe, efficient operation.
Baton Rouge, LA 70815
Completed fall heater tune-up on two Rheem air handler systems (approximately 5-6 years old), including inspection of the control compartments, transformer, and wiring connections. Verified electrical operation using a clamp meter to test the run capacitor and measure amperage draw on the control wiring, and noted light dust accumulation in the blower compartment with no visible damage, rust, or frost.
Completed fall heater tune-up on two Rheem air handler systems (approximately 5-6 years old), including inspection of the control compartments, transformer, and wiring connections. Verified electrical operation using a clamp meter to test the run capacitor and measure amperage draw on the control wiring, and noted light dust accumulation in the blower compartment with no visible damage, rust, or frost.
Asters D.
Asters D. Checked in
Completed fall heater tune-up on two Rheem air handler systems (approximately 5-6 years old), including inspection of the control compartments, transformer, and wiring connections. Verified electrical operation using a clamp meter to test the run capacitor and measure amperage draw on the control wiring, and noted light dust accumulation in the blower compartment with no visible damage, rust, or frost.
Baton Rouge, LA 70820
Performed seasonal heating system tune-up on the furnace, including inspection of the gas valve assembly, wiring, and burner/blower components, and measured electrical current draw with a clamp meter to verify proper operation. Inspected the evaporator coil and air handler cavity and documented significant rust and corrosion on the coil flange and drain pan area, along with dark staining on the insulation panel, which is recommended for further evaluation and cleaning.
Performed seasonal heating system tune-up on the furnace, including inspection of the gas valve assembly, wiring, and burner/blower components, and measured electrical current draw with a clamp meter to verify proper operation. Inspected the evaporator coil and air handler cavity and documented significant rust and corrosion on the coil flange and drain pan area, along with dark staining on the insulation panel, which is recommended for further evaluation and cleaning.
Joshua B.
Joshua B. Checked in
Performed seasonal heating system tune-up on the furnace, including inspection of the gas valve assembly, wiring, and burner/blower components, and measured electrical current draw with a clamp meter to verify proper operation. Inspected the evaporator coil and air handler cavity and documented significant rust and corrosion on the coil flange and drain pan area, along with dark staining on the insulation panel, which is recommended for further evaluation and cleaning.
Baton Rouge, LA 70817
Performed a pre-sale HVAC inspection on the AC and heating system, evaluating heater operation based on the reported heating issue. Inspection of the air handler revealed a blower wheel heavily caked with dust and debris, a corroded shaft collar and set screw, and rust and heavy buildup throughout the blower housing, all of which restrict airflow and can contribute to heating performance problems. Recommend cleaning or replacing the blower assembly and addressing the corroded components.
Performed a pre-sale HVAC inspection on the AC and heating system, evaluating heater operation based on the reported heating issue. Inspection of the air handler revealed a blower wheel heavily caked with dust and debris, a corroded shaft collar and set screw, and rust and heavy buildup throughout the blower housing, all of which restrict airflow and can contribute to heating performance problems. Recommend cleaning or replacing the blower assembly and addressing the corroded components.
Asters D.
Asters D. Checked in
Performed a pre-sale HVAC inspection on the AC and heating system, evaluating heater operation based on the reported heating issue. Inspection of the air handler revealed a blower wheel heavily caked with dust and debris, a corroded shaft collar and set screw, and rust and heavy buildup throughout the blower housing, all of which restrict airflow and can contribute to heating performance problems. Recommend cleaning or replacing the blower assembly and addressing the corroded components.
Baton Rouge, LA 70810
Performed a fall heating tune-up on one system, inspecting the furnace cabinet, control board wiring, and inducer/blower assembly for proper operation. Verified electrical performance with a clamp meter, measuring approximately 2.09 amps on the motor circuit, and observed the motor running smoothly. No signs of rust, frost, or damage were found, and the system was left operating normally.
Performed a fall heating tune-up on one system, inspecting the furnace cabinet, control board wiring, and inducer/blower assembly for proper operation. Verified electrical performance with a clamp meter, measuring approximately 2.09 amps on the motor circuit, and observed the motor running smoothly. No signs of rust, frost, or damage were found, and the system was left operating normally.
Asters D.
Asters D. Checked in
Performed a fall heating tune-up on one system, inspecting the furnace cabinet, control board wiring, and inducer/blower assembly for proper operation. Verified electrical performance with a clamp meter, measuring approximately 2.09 amps on the motor circuit, and observed the motor running smoothly. No signs of rust, frost, or damage were found, and the system was left operating normally.
Baton Rouge, LA 70820
Responded to a warranty call for inadequate cooling in the spare bedroom and living room. Measured supply air temperatures at the ceiling registers with an infrared thermometer (readings of 48.7°F and 40.8°F), indicating uneven airflow and temperature distribution between zones. Noted water staining on the ceiling around the supply vent, suggesting possible condensation or a moisture issue in the duct system that warrants further inspection.
Responded to a warranty call for inadequate cooling in the spare bedroom and living room. Measured supply air temperatures at the ceiling registers with an infrared thermometer (readings of 48.7°F and 40.8°F), indicating uneven airflow and temperature distribution between zones. Noted water staining on the ceiling around the supply vent, suggesting possible condensation or a moisture issue in the duct system that warrants further inspection.
Taylor B.
Taylor B. Checked in
Responded to a warranty call for inadequate cooling in the spare bedroom and living room. Measured supply air temperatures at the ceiling registers with an infrared thermometer (readings of 48.7°F and 40.8°F), indicating uneven airflow and temperature distribution between zones. Noted water staining on the ceiling around the supply vent, suggesting possible condensation or a moisture issue in the duct system that warrants further inspection.
Baton Rouge, LA 70816
Performed a diagnostic inspection and tune-up on a 15-year-old R-22 split system air handler located in the attic after reported water intrusion from a failed attic pipe. Inspected the plenum, flexible duct connections, and control compartment, noting corrosion and rust streaking on the casing, deteriorated and disordered duct taping and strapping, displaced insulation, debris accumulation, and tangled control wiring with possible moisture damage. Evaluated the unit's condition to support a second-opinion repair assessment and documented findings with photos for a detailed estimate of the repairs needed to restore system operation.
Performed a diagnostic inspection and tune-up on a 15-year-old R-22 split system air handler located in the attic after reported water intrusion from a failed attic pipe. Inspected the plenum, flexible duct connections, and control compartment, noting corrosion and rust streaking on the casing, deteriorated and disordered duct taping and strapping, displaced insulation, debris accumulation, and tangled control wiring with possible moisture damage. Evaluated the unit's condition to support a second-opinion repair assessment and documented findings with photos for a detailed estimate of the repairs needed to restore system operation.
Joshua B.
Joshua B. Checked in
Performed a diagnostic inspection and tune-up on a 15-year-old R-22 split system air handler located in the attic after reported water intrusion from a failed attic pipe. Inspected the plenum, flexible duct connections, and control compartment, noting corrosion and rust streaking on the casing, deteriorated and disordered duct taping and strapping, displaced insulation, debris accumulation, and tangled control wiring with possible moisture damage. Evaluated the unit's condition to support a second-opinion repair assessment and documented findings with photos for a detailed estimate of the repairs needed to restore system operation.
Baton Rouge, LA 70814
Responded to reports of a clogged condensate drain line and a non-communicating thermostat on the upstairs system. Inspected the air handler and found the drain pan heavily rusted and corroded with debris present, and checked electrical components with a clamp meter, measuring 0.61 A on the control wiring. Documented the pan corrosion and thermostat communication fault for further repair and system diagnostics.
Responded to reports of a clogged condensate drain line and a non-communicating thermostat on the upstairs system. Inspected the air handler and found the drain pan heavily rusted and corroded with debris present, and checked electrical components with a clamp meter, measuring 0.61 A on the control wiring. Documented the pan corrosion and thermostat communication fault for further repair and system diagnostics.
Asters D.
Asters D. Checked in
Responded to reports of a clogged condensate drain line and a non-communicating thermostat on the upstairs system. Inspected the air handler and found the drain pan heavily rusted and corroded with debris present, and checked electrical components with a clamp meter, measuring 0.61 A on the control wiring. Documented the pan corrosion and thermostat communication fault for further repair and system diagnostics.
Baton Rouge, LA 70810
Performed full tune-up inspections on two attic-mounted HVAC systems (a gas furnace/air handler unit and its associated components) as part of a pre-sale evaluation, checking the equipment, gas supply line, condensate drain assembly with shutoff valve, and electrical connections. Found a torn seam in the foil-faced flexible supply duct with insulation bulging through the split, along with compressed and uneven attic insulation, both of which are recommended for repair to restore duct integrity and efficiency.
Performed full tune-up inspections on two attic-mounted HVAC systems (a gas furnace/air handler unit and its associated components) as part of a pre-sale evaluation, checking the equipment, gas supply line, condensate drain assembly with shutoff valve, and electrical connections. Found a torn seam in the foil-faced flexible supply duct with insulation bulging through the split, along with compressed and uneven attic insulation, both of which are recommended for repair to restore duct integrity and efficiency.
Joshua B.
Joshua B. Checked in
Performed full tune-up inspections on two attic-mounted HVAC systems (a gas furnace/air handler unit and its associated components) as part of a pre-sale evaluation, checking the equipment, gas supply line, condensate drain assembly with shutoff valve, and electrical connections. Found a torn seam in the foil-faced flexible supply duct with insulation bulging through the split, along with compressed and uneven attic insulation, both of which are recommended for repair to restore duct integrity and efficiency.
Baton Rouge, LA 70817
Responded to an after-hours no-heat call on the downstairs gas furnace; unit is out of warranty. Inspected the control circuitry and limit/sensor wiring, and measured amperage on the blower motor circuit with a clamp meter, which read 1.99 A AC. Noted heavy corrosion on the exterior gas supply piping.
Responded to an after-hours no-heat call on the downstairs gas furnace; unit is out of warranty. Inspected the control circuitry and limit/sensor wiring, and measured amperage on the blower motor circuit with a clamp meter, which read 1.99 A AC. Noted heavy corrosion on the exterior gas supply piping.
Asters D.
Asters D. Checked in
Responded to an after-hours no-heat call on the downstairs gas furnace; unit is out of warranty. Inspected the control circuitry and limit/sensor wiring, and measured amperage on the blower motor circuit with a clamp meter, which read 1.99 A AC. Noted heavy corrosion on the exterior gas supply piping.
Baton Rouge, LA 70808
Installed a complete 3-ton gas split system with new R-8 insulated ductwork serving seven supply drops, sized and balanced to a 1,200 CFM design airflow per the room-by-room duct layout. Completed refrigerant charge verification using a digital manifold gauge on R410A, confirming operating pressures of 124.7 psi suction and 370.1 psi discharge with 7.3°F superheat and 28.2°F subcooling within specification.
Installed a complete 3-ton gas split system with new R-8 insulated ductwork serving seven supply drops, sized and balanced to a 1,200 CFM design airflow per the room-by-room duct layout. Completed refrigerant charge verification using a digital manifold gauge on R410A, confirming operating pressures of 124.7 psi suction and 370.1 psi discharge with 7.3°F superheat and 28.2°F subcooling within specification.
Taylor B.
Taylor B. Checked in
Installed a complete 3-ton gas split system with new R-8 insulated ductwork serving seven supply drops, sized and balanced to a 1,200 CFM design airflow per the room-by-room duct layout. Completed refrigerant charge verification using a digital manifold gauge on R410A, confirming operating pressures of 124.7 psi suction and 370.1 psi discharge with 7.3°F superheat and 28.2°F subcooling within specification.
Baton Rouge, LA 70816
Performed a second-opinion AC tune-up and system evaluation on a 2-ton electric split system to determine repair viability versus full replacement. Inspected the indoor air handler and found significant rust and corrosion on the cabinet panel, refrigerant line fittings, and bracket, along with a dirty coil and drain pan area and aged wiring. Verified electrical operation with a clamp meter amperage check, and documented all findings with photos so the customer can pursue repair options.
Performed a second-opinion AC tune-up and system evaluation on a 2-ton electric split system to determine repair viability versus full replacement. Inspected the indoor air handler and found significant rust and corrosion on the cabinet panel, refrigerant line fittings, and bracket, along with a dirty coil and drain pan area and aged wiring. Verified electrical operation with a clamp meter amperage check, and documented all findings with photos so the customer can pursue repair options.
Asters D.
Asters D. Checked in
Performed a second-opinion AC tune-up and system evaluation on a 2-ton electric split system to determine repair viability versus full replacement. Inspected the indoor air handler and found significant rust and corrosion on the cabinet panel, refrigerant line fittings, and bracket, along with a dirty coil and drain pan area and aged wiring. Verified electrical operation with a clamp meter amperage check, and documented all findings with photos so the customer can pursue repair options.
Baton Rouge, LA 70809
Review
Super kind, respectful and informative. Seemed really knowledgeable.
Natalie Smith - Baton Rouge, LA 70816
Completed comprehensive heater tune-up and inspection on single-system HVAC unit. Performed thorough cleaning of blower motor assembly, verified 1/6 HP Fasco motor operating within specifications at 208-230V, 3000 RPM. Inspected condensate drain pan and documented significant rust staining and sediment accumulation indicating prolonged water exposure and oxidation. Checked all electrical connections, PVC drainage lines, and verified proper airflow through blower housing. System operational upon completion of service.
Completed comprehensive heater tune-up and inspection on single-system HVAC unit. Performed thorough cleaning of blower motor assembly, verified 1/6 HP Fasco motor operating within specifications at 208-230V, 3000 RPM. Inspected condensate drain pan and documented significant rust staining and sediment accumulation indicating prolonged water exposure and oxidation. Checked all electrical connections, PVC drainage lines, and verified proper airflow through blower housing. System operational upon completion of service.
Asters D.
Asters D. Checked in
Completed comprehensive heater tune-up and inspection on single-system HVAC unit. Performed thorough cleaning of blower motor assembly, verified 1/6 HP Fasco motor operating within specifications at 208-230V, 3000 RPM. Inspected condensate drain pan and documented significant rust staining and sediment accumulation indicating prolonged water exposure and oxidation. Checked all electrical connections, PVC drainage lines, and verified proper airflow through blower housing. System operational upon completion of service.
Baton Rouge, LA 70816
Completed comprehensive heater tune-up including thorough cleaning and inspection of HVAC system components. Performed electrical diagnostics using clamp meter to verify proper amperage draw and system performance, documenting readings at control panel and terminal connections. Inspected attic ductwork, plenum connections, and insulation integrity to ensure proper airflow and energy efficiency throughout the heating system.
Completed comprehensive heater tune-up including thorough cleaning and inspection of HVAC system components. Performed electrical diagnostics using clamp meter to verify proper amperage draw and system performance, documenting readings at control panel and terminal connections. Inspected attic ductwork, plenum connections, and insulation integrity to ensure proper airflow and energy efficiency throughout the heating system.
Joshua B.
Joshua B. Checked in
Completed comprehensive heater tune-up including thorough cleaning and inspection of HVAC system components. Performed electrical diagnostics using clamp meter to verify proper amperage draw and system performance, documenting readings at control panel and terminal connections. Inspected attic ductwork, plenum connections, and insulation integrity to ensure proper airflow and energy efficiency throughout the heating system.
Baton Rouge, LA 70817
Review
AJ was very nice, he explained everything in detail, even reviewed findings. Definitely recommend. The other gentleman was nice also and Codie called to info of arrival times, etc.
Lee - Baton Rouge, LA 70811
Review
Michael Evetts - Baton Rouge, LA 70817
Review
Absolutely amazing service. Quite possibly the best experience I've ever had with an HVAC vendor. Couldn't recommend them more highly.
Brad Tiffee - Baton Rouge, LA 70810
Review
Astor’s was great got in got out and fixed the problem ASAP. Great man to have on your team!
Michael - Baton Rouge, LA 70820
Review
I called GeauxHVAC out for a routine heater and A/C maintenance cleaning, and I could not be more impressed with the whole experience. From start to finish, they were remarkably professional and completely transparent. I never felt that they were pushing unnecessary sales. They simply walked me through how my system was running and explained, in a way I could actually follow, how everything could work more efficiently. When I was ready to move forward with the recommended updates, they made scheduling and execution effortless. Communication from the office was wonderful. They sent reminders and provided real-time updates on when to expect the technician. Taylor arrived on a brutally hot afternoon after a tough prior job, but he stepped through the door with the brightest smile. He braved my sweltering attic, kept me informed throughout the process, replaced a burnt-out attic bulb, and meticulously swept up every stray bit of insulation before heading out. The difference is night and day! Our home at 74°F feels surprisingly crisp, and the unit no longer struggles against the Louisiana summer heat. The entire GeauxHVAC team is in sync, and I am so grateful for their care.
Sydney - Baton Rouge, LA 70810
Review
Taylor seemed to be very knowlegable pertaing to modern A/C systems. He seems like a person I could trust to give me reliable and accurate advice on my A/C system.
David - Baton Rouge, LA 70817
Review
Taylor and AJ gave excellent service with the install. They answered all of my questions and left my house better than before. I would rate a ten if I could. The whole experience has been wonderful.
Stephanie - Baton Rouge, LA 70816
Review
Great service
Glynn - Baton Rouge, LA 70810
Review
Very thorough, honest, and informational. Found issues and diagnosed problems.
Glynn - Baton Rouge, LA 70810
Review
Very knowledgeable, efficient, and timely in response to request.
Glynn - Baton Rouge, LA 70810
Review
Very informative, honest and friendly people to meet and have complete work in your home.
Margaret - Baton Rouge, LA 70809
Review
Wonderful and thorough service.
Alece - Baton Rouge, LA 70815
Review
As usual Joshua was thorough and completed the servicing of my HVAC to my satisfaction. I am very comfortable with Joshua. I trust his recommendations and when he tells me something needs to be done, I know it needs to be done! Excellent Technician!
Stella - Baton Rouge, LA 70816

Ready to schedule?

Book this service today and secure your preferred time.

Book now

Frequently Asked Questions

Answer common concerns before visitors call